Victron MPPT Solar Controller. Victron are world leaders in all things solar.
FEATURES
Battery Voltage: 12/24V
Rated charge current: 10A
Nominal PV power, 12 V (1a,b): 145W
Nominal PV power, 24 V (1a,b): 290W
Max. PV short circuit current (2): 13 A
Automatic load disconnect: Yes
Max. PV open circuit voltage: 75V
Peak efficiency: 98%
Self-consumption load on: 12 V: 19 mA 24 V: 16 mA
Self-consumption load off: 12 V: 10 mA 24 V: 8 mA
Charge voltage 'absorption': 14,4 V / 28,8 V (adjustable)
Charge voltage 'float': 13,8 V / 27,6 V (adjustable)
Charge algorithm: multi-stage adaptive
Temperature compensation: -16 mV / C resp. -32 mV / C
Max. continuous load current: 15A
Low voltage load disconnect: 11,1 V / 22,2 V / 44,4 V or 11,8 V / 23,6 V / 47,2 V or Battery Life algorithm
Low voltage load reconnect: 13,1 V / 26,2 V / 52,4 V or 14 V / 28 V / 56 V or Battery Life algorithm
Protection: Output short circuit / Over temperature
Operating temperature: -30 to +60 C (full rated output up to 40 C)
Humidity: 95 %, non-condensing
Data communication port: VE.Direct (see the data communication white paper on Victron website)
Load output
Over-discharge of the battery can be prevented by connecting all loads to the load output. The load output will disconnect the load
when the battery has been discharged to a pre-set voltage.
Alternatively, an intelligent battery management algorithm can be chosen: see Battery Life.
The load output is short circuit proof.
Battery Life: intelligent battery management
When a solar charge controller is not able to recharge the battery to its full capacity within one day,
the result is often that the battery will continually be cycled between a partially charged state and the
end of discharge state. This mode of operation (no regular full recharge) will destroy a lead-acid battery
within weeks or months.
The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day
slightly increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy
is sufficient to recharge the battery to nearly the full 100 %. From that point onwards, the load disconnect
level will be modulated so that a nearly 100 % recharge is achieved about once every week.
Programmable battery charge algorithm - See the software section on our website for details
Day/night timing and light dimming option - See the software section on our website for details
Internal temperature sensor - Compensates absorption and float charge voltage for temperature.
Optional external battery voltage and temperature sensing via Bluetooth
A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage
and temperature to one or more SmartSolar Charge Controllers.
Fully discharged battery recovery function
Will initiate charging even if the battery has been discharged to zero volts.
Will reconnect to a fully discharged Li-ion battery with integrated disconnect function.